    uedbet官网手机版网扯-手机uedbet平台下载 is a high and new technology enterprise with science and technology, talent intensive. The company specialized is engaged in the research and development, production and sales for the "big diameter water meter" and "intelligent long-transmiting big water meter". The company has strong r&d team, with the domestic water meter industry veteran superb technical experts, and with German technology as the foundation, adjust measures to local conditions, the introduction and development of a variety of contemporary international level suitable for the use of the environment of large diameter meter, such as belt thread interface D40 big range water meter (national patent no. : ZL201120546724.8 and ZL201130494406.7), for the domestic initiative.

    The management team of company also keenly aware, technology and talent is the key to the success of the enterprise, the company start to notice all the technology investment, at introduction of patent technology, and technical personnel and advanced technology and equipment, service is more on the pursuit of distinctive core concept "to do the best"; Companies follow the "leading technology, market orientation, pragmatic innovation, steady development" policy, adhere to the quality of survival, in good faith and development, to "management should benefit" the guiding ideology, service to the society.

    Company has created a number of elite technical personnel, with acute market consciousness of the marketing personnel, the modern enterprise management personnel and a well-trained staff, my company is eager to friends from all walks of life on the basis of mutual benefit, in a wide range of technical cooperation, communication negotiations, further develop the market sales network, and create new performance, and keep the sustainable development of the company, and on this basis to the measurement of large diameter meter field peak impact.

    Your requirement is our goal, Fuzhou Kerong will, as always create brilliant with customer!

    We await your presence...

    PRODUCTS

  • WPH
  • LXLG
  • WS
  • APPLICATION

    Measuring the volume of cold (hot) water passing through the pipeline

    FEATURES

    1. magnesium aluminum alloy die-casting cover

    2. Dry-dial,magnetic drive

    3. Vacuum sealed counter,keeps clear reading for long time

    4. Removable measuring insert,easy installation and maitenance

    5. High overload security

    6. Wide measuring range

    7. Measuring high flowrate with low head loss

    8. Outstanding long-term accuracy even under extremeloads

    9. Remote transmission device can be added upon request,Many kinds of sensors,such as Reed Switch ,Hall and Weagand canbe supplied upon request Pulse output may be 10 l/pulse ,100 l/pulse,1000 l/pluse

    WORKING CONDITION

    Water temperature≤50℃(Hot water meter≤90℃)

    Water pressure≤1Mpa

    MAXIMUM PERMISSIBLE ERROR

    From the minimum flow-rate (qmin) inclusive to the lower zone of the transitionalflow-rate (qt) exclusive: ±5%

    From the transitional flow-rate (qt) inclusive to the higher zone of the maximumflow-rate (qmax) exclusive: ±2%(hot water meter±3%.)

    Technical Data

    Nominal Diameter DN
    mm
    40
    50
    65
    80
    100
    125
    150
    200
    250
    300
    Nominal flowrate Qn
    m3/h
    15
    15
    25
    40
    60
    100
    150
    250
    400
    600
    Maximum flowrate(short-term) Qmax
    m3/h
    60
    80
    120
    150
    250
    300
    350
    650
    1200
    1500
    Maximum flowrate (constant)
    m3/h
    30
    40
    60
    90
    125
    170
    250
    325
    600
    700
    Transitional flowrate Qt
    m3/h
    3.0
    3.0
    5.0
    8.0
    12.0
    20.0
    30.0
    50.0
    80.0
    120
    Minimum flowrate Qmin
    m3/h
    0.45
    0.45
    0.75
    1.2
    1.8
    3.0
    4.5
    7.5
    12.0
    18.0
    Display range
    Min
    `
    0.0005
    0.005
    Max
     
    999999.999
    9999999.99
    Mating dimensions
    Outside diameter of flange D
    mm
    150
    165
    185
    200
    220
    250
    285
    340
    395
    445
    Diameter of bolt circle D1
    mm
    110
    125
    145
    160
    180
    210
    240
    295
    335
    410
    Diameter of bolt holes
    mm
    18
    18
    18
    19
    19
    19
    23
    23
    27
    27
    `Bolts
    Number
     
    4
    4
    4
    4/8
    8
    8
    8
    8/12
    12
    12
    Nominal size
    mm
    M16
    M16
    M16
    M16
    M16
    M16
    M20
    M20
    M24
    M24
    Height H
    mm
    198
    205
    218
    280
    290
    305
    320
    365
    420
    660
    Height to remove measuring insert G
    mm
    228
    228
    228
    338
    338
    338
    338
    356
    400
    620
    Overall length L
    mm
    200
    200
    200
    225
    250
    250
    300
    350
    450
    500

    FEATURES

    1. Copper cover

    2. Dry-dial,magnetic drive

    3. Vacuum sealed counter,keeps clear reading for long time

    4. Removable measuring insert,easy installation and maitenance

    5. Measuring hig flowrate with low head loss

    6. Outstanding long-term accuracy even under extremeloads

    WORKING CONDITION

    Water temperature≤50℃

    Water pressure≤1Mpa

    MAXIMUM PERMISSIBLE ERROR

    From the minimum flow-rate (qmin) inclusive to the lower zone of the transitionalflow-rate (qt) exclusive: ±5%

    From the transitional flow-rate (qt) inclusive to the higher zone of the maximumflow-rate (qmax) exclusive: ±2%(hot water meter±3%.)

    Technical Data

    Nominal Diameter DN
    mm
    50
    65
    80
    100
    125
    150
    200
    Nominal flowrate Qn
    m3/h
    15
    25
    40
    60
    100
    150
    250
    Maximum flowrate Qmax
    m3/h
    30
    50
    80
    120
    200
    300
    500
    Transitional flowrate Qt
    m3/h
    3.0
    5.0
    8.0
    12.0
    20.0
    30.0
    50.0
    Minimum flowrate Qmin
    m3/h
    0.45
    0.75
    1.2
    1.8
    3.0
    4.5
    7.5
    Display range
    Min
    `
    0.002
    0.02
    Max
     
    999999.99
    9999999.9
    Mating dimensions
    Outside diameter of flange D
    mm
    165
    185
    200
    220
    250
    285
    340
    Diameter of bolt circle D1
    mm
    125
    145
    160
    180
    210
    240
    295
    Diameter of bolt holes
    mm
    18
    18
    19
    19
    19
    23
    23
    `Bolts
    Number
     
    4
    4
    4/8
    8
    8
    8
    8/12
    Nominal size
    mm
    M16
    M16
    M16
    M16
    M16
    M20
    M20
    Height H
    mm
    205
    218
    280
    290
    305
    320
    365
    Height to remove measuring insert G
    mm
    228
    228
    338
    338
    338
    338
    356
    Overall length L
    mm
    200
    200
    225
    250
    250
    300
    350

    FEATURES

    1. For horizontal installation

    2. Removeable measuring insert, easy installation and maintenance

    3. Stainless strainer inside

    4. Magnesium aluminum alloy die-casting cover

    5. Dry-dial, magnetic drive

    6. Vacuum sealed counter,keeps clear reading for long time

    7. Extended measuring range better than metrological class

    8. Outstanding long-term accuracy even under extremeloads

    WORKING CONDITION

    Water temperature≤50℃(Hot water meter≤90℃)

    Water pressure≤1Mpa

    MAXIMUM PERMISSIBLE ERROR

    From the minimum flow-rate (qmin) inclusive to the lower zone of the transitionalflow-rate (qt) exclusive: ±5%

    From the transitional flow-rate (qt) inclusive to the higher zone of the maximumflow-rate (qmax) exclusive: ±2%(hot water meter±3%.)

    Technical Data

    Nominal Diameter DN
    mm
    40
    50
    65
    80
    100
    150
    200
    Nominal flowrate Qn
    m3/h
    15
    15
    25
    40
    60
    150
    250
    Maximum flowrate(short-term) Qmax
    m3/h
    50
    50
    50
    80
    125
    315
    500
    Maximum flowrate (constant)
    m3/h
    40
    40
    40
    60
    100
    250
    400
    Transitional flowrate Qt
    m3/h
    3.0
    3.0
    5.0
    8.0
    12.0
    30.0
    50.0
    Minimum flowrate Qmin
    m3/h
    0.45
    0.45
    0.75
    1.2
    1.8
    4.5
    7.5
    Display range
    Min
    ` m3
    0.0005
    Max
    m3
    999999.9995
    Mating dimensions
    Outside diameter of flange D
    mm
    150
    165
    185
    200
    220
    285
    340
    Diameter of bolt circle D1
    mm
    110
    125
    145
    160
    180
    240
    295
    Diameter of bolt holes
    mm
    18
    18
    18
    19
    19
    23
    23
    `Bolts
    Number
     
    4
    4
    4
    4/8
    8
    8
    8/12
    Nominal size
    mm
    M16
    M16
    M16
    M16
    M16
    M20
    M20
    Height H
    mm
    228
    228
    228
    282
    303
    430
    505
    Height to remove measuring insert G
    mm
    268
    268
    268
    344
    350
    565
    680
    Overall length L
    mm
    280
    280
    270
    300
    370
    225
    370
    250
    500
    500

    CONTACT US

    Fuzhou Kerong Water Meter Co., Ltd

  • Tel: +86 591 83515373
  • Fax: +86 591 87141715
  • E-mail: cxdudu@sina.com
  • Zip code: 350008
  • Address: NO.1-1, Wucuo edge of Qi an village, Gaishan town Cangshan District of Fuzhou, Fujian,China
  • Website: http://www.fzkerong.com